1. Pure lightcontrol mode: When there is no sunlight, the light intensity drops to thestarting point. After the controller delays for 10 minutes to confirm the startsignal, the load is turned on according to the set parameters and the loadstarts to work. When there is sunlight, the light intensity rises to startPoint, the controller delays the output for 10 minutes after confirming theshutdown signal, and the load stops working.
2. Light control+ time control mode: The startup process is the same as that of pure lightcontrol. When the load works until the set time, it will automatically turnoff. The set time is 1 to 14 hours.
3. Manual mode:In this mode, the user can control the opening and closing of the load throughthe keys, regardless of whether it is day or night. This mode is used for somespecial loads or debugging.
4. Debug mode:It is used for system debugging. The load is turned off when there is a lightsignal, and the load is turned on without a light signal.
5. Normally openmode: The load is always in the output state when it is powered on. This modeis suitable for loads that require 24-hour power supply.
6. Real-timecontrol mode: the load can be turned on or off according to the real time
6. Real-timecontrol mode: the load can be turned on or off according to the real time